USB Type-C Power Delivery (PD) designs may need to accept power from a connector in one operating state and supply power to it in another. Managing both directions calls for more than a simple series switch: the power path must also handle startup current, voltage faults, reverse current, and thermal stress. The AOZ1380DI combines separate sink and source switches with control and protection circuitry for these tasks.

For engineers designing USB-C power interfaces, the key considerations are how the two paths operate, which protections apply to each, and how component selection and PCB layout affect system behavior. Understanding those details helps translate the device’s electrical features into a power architecture that can be evaluated against its operating requirements.

Two power paths, one operating mode at a time

The AOZ1380DI integrates two back-to-back MOSFET paths. In sink mode, power flows from USB VBUS to VCHG, the output connected to the battery charger or downstream system. In source mode, power flows from a 5 V supply at V5V to the connector’s VBUS. The device supports USB Type-C PD sink and source operation, but only one mode can be active at a time; the sink and source enable inputs select the respective path.

Back-to-back MOSFETs allow each path to block unwanted reverse current when disabled or when the output rises above the input. The sink path has a typical on-resistance of 20 mΩ and operates over a 3.4 V to 22 V VBUS range. It supports up to 10 A continuous sink current and a specified 20 A pulse for 10 ms at a 2% duty cycle. The source path has a typical on-resistance of 39 mΩ and accepts 3.4 V to 5.5 V at V5V, with source current limited to a programmable maximum of 3.5 A.

Sink-mode protection and startup

The sink path monitors VBUS for under-voltage and over-voltage conditions. Under-voltage lockout prevents turn-on until the input is above the device’s operating threshold. Over-voltage protection is set through the POVP pin: grounding it selects a nominal 24 V threshold, while leaving it open selects 5.8 V. When the threshold is exceeded, the switch is turned off or kept off, and the open-drain FLTB_SNK output reports the fault by pulling low.

Sink startup uses an external capacitor at SS_SNK to set the output voltage ramp. As VCHG rises toward VBUS, the switch temporarily operates in its linear region, where it dissipates power. The relevant load during this interval includes both current used to charge output capacitance and current drawn by the downstream system. Designers should therefore assess startup conditions—not just steady-state current—against the switch’s safe operating area and thermal design.

The active-low sink enable also supports dead-battery operation. True reverse current blocking (TRCB) turns off the sink path if VCHG exceeds VBUS by the specified threshold, helping prevent current from flowing back toward the connector. The sink fault output also signals TRCB and thermal shutdown events.

Source-mode current limiting and Fast Role Swap

In source mode, an external resistor at ILIM sets the over-current threshold. The datasheet provides resistor-to-current relationships; for example, 14.3 kΩ corresponds to a nominal 1 A threshold. Under over-current, FLTB_SRC is asserted after the specified fault delay. A severe overload or short circuit can cause significant switch dissipation and may lead to thermal shutdown.

The source path includes internal soft-start to manage inrush when charging output capacitance. Its normal turn-on time is specified as 2.7 ms under the datasheet’s stated test conditions. For Fast Role Swap (FRS), the FON input enables faster turn-on when asserted before the source path is enabled. In this fast-turn-on condition, soft-start and over-current protection are disabled. This behavior makes the control sequence important: FRS operation should be designed with awareness of the protection trade-off and the required timing.

Source-mode TRCB turns off the switch when connector-side VBUS rises above the 5 V input, then allows the path to turn on again after the reverse-current condition clears. The device also supports fast recovery from TRCB. As in sink mode, UVLO, over-voltage monitoring, and thermal shutdown provide additional safeguards, while FLTB_SRC reports source-path faults.

Designing the surrounding power path

Protection-switch selection is only one part of a robust implementation. The external capacitors and PCB need to support the expected electrical and thermal conditions:

  • VBUS capacitance: The datasheet notes a 10 µF maximum on VBUS for USB specifications and recommends using that maximum value for noise immunity against system noise and cable plug or unplug transients.
  • V5V input capacitance: A 20 µF ceramic capacitor is recommended close to the V5V pin to support switching transients and reduce input-voltage disturbance.
  • VCHG bulk capacitance: Size the sink output capacitance for downstream transient demand. Excessive capacitance can affect startup; if VCHG remains approximately 300 mV below the input at the end of soft-start, short-circuit protection may activate.
  • Thermal layout: The exposed pad is electrically isolated and is the common drain node of the internal sink switches. It must not be treated as ground. The datasheet recommends connecting it to electrically isolated copper thermal islands across PCB layers using multiple vias, with as much copper area as practical.

The device’s two fault outputs are open-drain signals and require pull-up resistors. Their independent reporting helps system logic distinguish sink-path faults from source-path faults. The ordering options also differ in fault recovery: AOZ1380DI-01 uses auto-recovery, while AOZ1380DI-02 is a latch-off option noted as available through sales contact.

Practical implications

A dual-path USB Type-C PD switch can simplify the implementation of controlled sink and source routes, but the design still depends on correct mode sequencing, suitable current-limit and soft-start choices, and careful fault handling. Engineers should verify transient and startup conditions as well as steady-state loading, account for FRS behavior, and preserve electrical isolation around the exposed thermal pad. These checks help ensure that the protection strategy matches the system’s actual power-flow and thermal requirements.