The AV9 preamp processor is designed to manage multiple audio and video sources in a home-cinema system, with provisions for separate-zone playback and external control. For system integrators and technical decision-makers, its main lesson is architectural: format conversion, signal routing and control are distinct functions, and each connection must be planned around what the processor actually supports.

The unit accepts analogue and digital audio, several forms of analogue video, and HDMI. It can route selected sources to a main system and provide analogue audio and composite video for a second zone. However, it does not convert every input format to every output format. Understanding these boundaries before installation helps avoid missing audio, blank displays or incorrect expectations about second-zone operation.

AV9 signal routing: separate formats, separate paths

The AV9 provides switching and volume control for multiple analogue and digital sources. Its inputs are labelled for common devices such as DVD, CD, satellite and VCR, but the manual notes that the input circuits are functionally equivalent. An unused input can therefore be assigned to a different source, provided the configuration and cabling are arranged accordingly.

For digital source equipment, connecting both its digital and analogue outputs can support different system needs. The digital connection can serve the main listening zone, while the analogue connection can be used for analogue recording or Zone 2. This is particularly important because Zone 2 does not receive audio through the AV9’s digital processing path.

On digital audio inputs, the AV9 can associate each input with a selected audio source through the setup menu. Its digital output passes through an incoming digital signal when a digital source is selected. When an analogue-only source is selected, the processor digitises it for the digital output, subject to operating-mode exceptions: the output is muted when Neo:6 or Pro Logic IIx processing is active. It is also muted when the selected source is connected only through HDMI; HDMI audio is not routed to that digital output.

Video switching does not mean format conversion

The AV9 switches video but does not convert between composite, S-video, component, RGB and HDMI. A source connected using composite video must be viewed through a composite output; the signal will not appear on an S-video or component output through conversion. The same principle applies to the other formats.

For integrators, the practical requirement is to match each source connection to the display path. Where a source offers more than one video output, connecting multiple formats can allow a higher-quality format to serve the main display while a composite or S-video connection supports recording or a secondary display. The manual ranks component/RGB above S-video, and S-video above composite in its stated video-quality hierarchy.

HDMI is also handled as a switching path rather than a conversion path. The AV9 has five HDMI inputs and one HDMI output, but analogue video cannot be routed to HDMI, nor can HDMI be converted to analogue video. An HDMI-only connection therefore does not provide a corresponding analogue video feed for Zone 2.

Planning Zone 2 connections

Zone 2 is intended to route and control analogue audio and composite video independently for a separate listening or viewing area. The AV9 does not provide analogue-to-digital conversion, digital-to-analogue conversion or DSP processing for Zone 2 signals. Consequently, connecting a source to the AV9 digitally is not enough to make its audio available in the second zone: the source’s analogue audio outputs must also be connected.

The video requirement is similarly specific. Since the AV9 does not convert video formats, a source must have a composite video connection to the processor for its picture to be available in Zone 2. This can matter even when the main system uses HDMI, component or S-video. A source intended for both zones may therefore need parallel connections in different formats.

Zone 2 audio outputs are line-level and should connect to an appropriate input on a separate amplifier. The processor also provides a composite video output for a second display. These connections should be included in the system design from the outset rather than treated as an afterthought.

External control and system integration

The AV9 supports front-panel and infrared remote operation, along with an RS232 serial control connection. The RS232 port is intended for compatible control systems and can also be used for software upgrades. Its serial programming interface is documented in the product handbook, making it the relevant reference for integrators developing or configuring a control-system link.

Infrared connections extend control beyond the front panel. A local IR input can be used when the receiver is obstructed, while a separate Zone 2 IR input allows remote operation from the second area. An IR output can relay commands to source components, either through compatible connections or an emitter positioned at a component’s IR sensor.

Three trigger outputs can coordinate the AV9 with other equipment. The 12V trigger provides separate main-zone and Zone 2 status signals for compatible devices, such as power amplifiers. Two additional video trigger outputs behave according to the configured video status: screen-control mode or SCART mode. Integrators should verify the selected mode and the receiving device’s requirements before connecting these outputs.

Setup, calibration and installation considerations

Correct operation depends on completing the setup process for the connected system. Basic configuration includes speaker sizes, subwoofer presence, speaker delays and channel levels. Speaker delay settings are based on measurements from the normal listening position to each speaker. The AV9’s setup menu can express these distances or times in selected units; changing the units resets entered delay values, so the measurement system should be chosen first.

For initial setup, the manual recommends using the composite video output to display the on-screen menu. The OSD is not available over HDMI, and high-quality video modes may not display the setup interface as expected. This is a useful commissioning detail: establish a reliable setup display path before relying on the final video configuration.

Installation also affects reliability. The AV9 requires adequate ventilation, a firm level surface and an intact protective earth connection. The manual recommends keeping audio and video cables away from power cabling where practical, using cables suited to their signal type, and observing the specified 75-ohm impedance for digital and video connections.

Practical implications for integrators

The AV9’s capabilities are best understood as a collection of defined signal paths rather than a universal format converter. A robust design should document which connections serve the main zone, recording outputs and Zone 2; provide analogue audio and composite video wherever secondary-zone use is required; and confirm control and trigger behavior during commissioning.

These principles apply directly to planning any multi-source AV installation: verify format compatibility end to end, distinguish switching from conversion, and configure the processor to match the actual speakers and displays. With those details addressed, the AV9 can serve as a central switching and control point without relying on unsupported routing assumptions.