A vehicle exhaust gas detector built from combined sensors offers a practical example of how embedded electronics can collect, process and communicate environmental measurements. The Emission Gas Detector (EGD) described in a 2018 study brought together three gas sensors, an Arduino Uno R3 controller and Bluetooth connectivity to assess motorcycle exhaust. For automation professionals, the design illustrates key instrumentation principles: selecting sensors for different measurements, converting analog signals into digital data, checking readings against a reference instrument and making results accessible to operators.

How the combined-sensor detector works

The EGD was designed to measure hydrocarbons (HC), carbon monoxide (CO), carbon dioxide (CO2) and oxygen (O2) in motorcycle exhaust. It uses a TGS-2201 sensor for HC and CO, an MG-811 sensor for CO2 and a TGS-2602 sensor for O2. Each sensor responds to the gas environment by producing an electrical output. The system routes these analog signals through the Arduino’s analog-to-digital conversion process so the controller can process and display the measurements.

This arrangement demonstrates a common approach to multi-parameter instrumentation: combine sensing elements with different response characteristics, then use a central controller to coordinate acquisition and output. The sensor readings are not direct digital measurements; they must first be converted and interpreted by the electronics. The study also reports that sensor output changed between indoor air, outdoor air and outdoor air containing gas, underscoring the influence of the surrounding environment on measurements.

From sensor readings to operator information

The Arduino Uno R3 serves as the system’s control point, linking the sensors, analog inputs and display. A Bluetooth HC-05 module transmits the results to an Android smartphone, while the study also describes displaying readings on a PC. This communication path makes measurement data available away from the controller itself and supports real-time viewing as described by the authors.

In an industrial monitoring context, the broader design lesson is to treat data acquisition and data presentation as connected parts of the instrument. A sensor signal has limited operational value if users cannot readily access or interpret it. Here, the controller handles the measurement workflow, while Bluetooth provides a wireless link to a user-facing device. The prototype was intended to make the results easy to view without a lengthy measurement process.

Calibration against a reference analyzer

To assess the EGD, the researchers compared it with an Infrared-205 “Pony” gas analyzer used by the North Sumatra environmental department. The detector was positioned at the motorcycle exhaust, and the EGD and reference analyzer measured the same exhaust components. The study reports that measurements were repeated five times and averaged for comparison.

Across three fuel groups, the average readings from the EGD were higher than the standard analyzer for CO, CO2 and HC, while the reported O2 averages were lower. For example, the reference analyzer measured average HC concentrations of 302 ppm, 494 ppm and 584 ppm across the three groups; the EGD readings were 318 ppm, 528 ppm and 624 ppm, respectively. These comparisons show why calibration against a reference instrument matters: a sensor system’s readings should be evaluated rather than assumed to match a standard analyzer.

The reported percentage error varied by gas and fuel group. The minimum was 5.2% for HC measurement in the Pertamax group, while the maximum was 13.08% for CO2 measurement in the Pertalite group. These figures describe the tested prototype and conditions; they should not be treated as universal accuracy specifications for the sensors or for other measurement setups.

What the motorcycle tests revealed

The researchers tested 15 motorcycles using three fuel types: Pertamax, Pertalite and Premium. They assessed exhaust quality using the measured gas levels and reported an overall distribution of eight motorcycles rated bad, four medium and three good. Results varied among the tested groups. The five Pertamax motorcycles included four rated good and one medium; the Pertalite group included bad and medium ratings, while all five Premium-fueled motorcycles were rated bad in the study.

The authors also noted that fuel type alone did not explain every result. Vehicle age, distance traveled and maintenance history were discussed as factors associated with measured emissions. The findings are specific to the sample and test conditions, so they do not establish a general ranking for all motorcycles or operating environments.

Practical considerations for measurement systems

For engineers and system integrators developing gas-monitoring equipment, this prototype highlights several useful checks:

  • Define each measurement channel: Match the sensor and signal path to the gas being monitored.
  • Account for ambient conditions: The study observed different sensor outputs in indoor, outdoor and gas-exposed conditions.
  • Validate against a reference: Compare readings with an established analyzer and report the measurement differences.
  • Make results accessible: Consider how operators will view and interpret measurements, including any wireless data link.

The EGD study does not establish industrial suitability, continuous-monitoring performance or compliance with emissions regulations. Its value is as a documented example of integrating gas sensors, a microcontroller and wireless reporting, alongside a direct comparison with a standard analyzer.

Conclusion

A combined-sensor vehicle exhaust gas detector can bring multiple measurements into a single embedded system and make results available through a local display or smartphone connection. The prototype’s comparison with a reference analyzer also shows that measurement error must be characterized for each gas and test condition. For automation professionals, the practical takeaway is straightforward: sensor integration is only one part of a reliable monitoring solution. Environmental effects, calibration, data handling and clear presentation all matter when turning raw signals into useful operational information.

Access Official Technical PDF

About The Author