A bifacial PVT air collector combines photovoltaic electricity generation with solar air heating, using a solar module that can absorb radiation from both its front and rear surfaces. For engineers and technical decision-makers assessing onsite solar options, this design offers a way to produce electrical and thermal energy from a single collector. Its performance, however, depends on more than the choice of solar cell: airflow configuration, rear-side illumination, reflector properties and collector construction all affect the results.
How a photovoltaic thermal air collector works
A photovoltaic thermal (PVT) collector integrates a PV panel with a thermal collector. The PV cells convert some incoming solar radiation into electricity, while the collector transfers heat to a working fluid. In an air-based system, air passes through one or more channels in the collector and carries away useful heat. Potential applications identified for PVT air collectors include solar drying and solar air heating.
Combining the two functions makes it possible to use the collector for both electrical output and heat delivery. Evaluation can therefore include electrical and thermal performance, as well as energy and exergy efficiency. Energy efficiency accounts for useful energy outputs in relation to energy input; exergy analysis considers the quality or usefulness of that energy. These measures describe different aspects of system performance and should not be treated as interchangeable.
Monofacial and bifacial solar cells
In a conventional monofacial PV module, the front surface receives sunlight, while the rear surface is opaque and does not function as an active light-collecting face. A bifacial module has active surfaces on both sides, allowing it to capture radiation at the front and light reflected toward its rear. That additional rear-side contribution is the key distinction when integrating bifacial cells into a PVT air collector.
The amount of rear-side energy available depends in part on the reflector beneath the panel. Reflector type and reflectance influence how much light returns to the rear surface. The reviewed studies describe diffuse, mirror and semi-mirror reflectors; one reported comparison found higher average reflectance for a white diffuse reflector than for several other tested colors. These findings illustrate why reflector choice and the installation beneath a bifacial module matter when assessing a design.
Bifacial panel efficiency is also influenced by the electrical performance of both faces, glazing transmittance, reflector performance and the panel’s packing factor. The packing factor is the proportion of the panel area occupied by active PV cells. These variables help explain why a bifacial module’s additional output is not a fixed value that applies to every installation.
Bifacial PVT air collector designs and airflow
Air-based PVT collectors can be classified by where air flows relative to the absorber and whether the system uses a single or multiple passes. Bifacial designs reviewed in the literature included four configurations:
- Single path: Air flows between the PV lamination and a reflector.
- Parallel paths: Air flows through channels above and below the PV lamination.
- Double path: A second air stream passes in the opposite direction to the first.
- Return-flow arrangement: Air passes between glazing and the PV lamination before returning through another channel.
In a comparison of these designs, the parallel-flow model recorded the highest reported total energy efficiency, at 51%–67%. The double-path and return-flow arrangements followed, with ranges of 47%–62% and 42%–56%. The single-path model had the lowest energy-efficiency range, at 28%–49%, but the highest reported exergy efficiency, at 8.2%–8.4%. This difference is a useful reminder that a configuration leading on one metric may not lead on another.
Studies also found that a semi-mirror reflector produced higher total power output than a diffuse reflector in a bifacial PVT air collector. Design comparisons should therefore consider the intended balance of electricity, heat and exergy performance rather than relying on one efficiency figure alone.
What reported efficiency ranges tell system evaluators
The review reports that bifacial PVT air collectors produced approximately 40% more electrical energy than monofacial PVT collectors. This is a reported comparison, not a guaranteed improvement for every system; rear-side illumination and system design are among the factors that affect the result.
Reported efficiency ranges also vary across studies. The review’s abstract gives monofacial PVT air collector energy efficiencies of 27%–94% and exergy efficiencies of 4%–18%. For bifacial collectors, it reports energy efficiencies of 28%–67% and exergy efficiencies of 8.2%–8.4%. The wide monofacial ranges reflect differences in collector design and test conditions, including absorber heat-transfer area, fins or corrugated surfaces, airflow arrangement and the presence or absence of glazing. Figures from separate studies should be interpreted in that context, not as direct comparisons under identical conditions.
For practical evaluation, engineers and project teams can focus on the factors that shape the operating point and useful output:
- Determine whether the application prioritizes electrical output, heated air or a combination of both.
- Compare single-pass and multi-pass airflow arrangements against the required thermal performance.
- Assess how the reflector and the area beneath the panel support rear-side light capture.
- Review energy and exergy results separately, noting the collector design and conditions behind each figure.
Practical implications
Bifacial PVT air collectors offer a combined approach to solar electricity and heat, with the potential for higher electrical generation than monofacial PVT designs. Their performance is shaped by the interaction of PV surfaces, reflectors and air-channel configuration. For technical decision-makers, the central takeaway is to evaluate the complete collector rather than the module alone: compare airflow designs, consider the rear-side optical environment, and match efficiency measures to the intended application. That system-level assessment provides a more useful basis for selecting or developing a PVT air collector.