Gamma-ray irradiation effects on power MOSFETs can extend beyond familiar shifts in threshold voltage and drain current. For switching circuits, changes to device capacitance can also matter: they may alter gate-drive requirements, switching speed and losses. Testing of commercial silicon (Si) and silicon carbide (SiC) devices under cobalt-60 exposure found dose-dependent shifts in input, output and reverse-transfer capacitances, with results that varied by device and dose.
For engineers designing power electronics for radiation environments, the practical point is that static electrical measurements alone may not describe how a transistor behaves in a switching application. Capacitance-voltage characterization provides another way to assess whether radiation exposure could affect circuit operation.
How total ionizing dose affects a power MOSFET
Ionizing radiation can generate electron-hole pairs in a MOSFET’s oxide. Some charge carriers escape, while others become trapped in the oxide or near the oxide-semiconductor interface. As dose accumulates, these trapped charges and radiation-related interface defects can change the device’s electrical characteristics. This cumulative exposure is called total ionizing dose (TID).
Radiation-induced charge can influence leakage, threshold voltage and current drive. It can also affect capacitance, which is central to how quickly a power MOSFET switches. The devices examined included a Toshiba Si MOSFET and two Rohm SiC MOSFETs. Measurements were taken before irradiation and after cobalt-60 doses of 50, 100, 300 and 600 krad, with drain-source voltage varied during characterization.
The study related capacitance changes to defects in the oxide and at the interface. In particular, changes in gate-to-drain capacitance can contribute to shifts in all three commonly reported terminal capacitances:
- Ciss, input capacitance, relates to the gate’s charging requirements.
- Coss, output capacitance, affects charge and discharge behavior at the output during switching.
- Crss, reverse-transfer capacitance, represents the gate-to-drain capacitance and influences coupling between the drain and gate.
These measurements are voltage-dependent: capacitance can change as drain-source voltage changes. Radiation may therefore alter not just a nominal capacitance value, but the device’s capacitance-voltage behavior.
Gamma-ray irradiation effects on Si and SiC capacitance
The measured responses were not uniform across device types or capacitances. At 50 krad, the reported capacitance curves showed little change from the pre-irradiation measurements. At higher doses, shifts became more apparent, but their direction and magnitude differed among the tested devices. This variation is important: the results do not support treating all SiC MOSFETs, or all power MOSFETs, as having the same radiation response.
For the tested Si device, output and reverse-transfer capacitances increased at some higher dose levels, while input capacitance showed a different pattern, including a decrease at 300 krad over the measured voltage range. The two SiC devices also responded differently from one another. For example, the reported output-capacitance changes for the 1200 V and 1700 V SiC devices did not follow the same direction at higher doses. The findings point to device- and component-specific behavior rather than a simple rule that SiC capacitance always changes less than Si capacitance.
The study reported that the tested MOSFETs operated within specification up to 100 krad and could operate after exposure up to 300 krad when a 0 V gate bias was used to turn them off. These observations apply to the devices and test conditions examined; they should not be taken as a general radiation rating for other parts or applications.
Why capacitance shifts matter in switching circuits
In a switching converter, capacitance changes can affect both control and power-stage behavior. If Ciss increases, the gate driver must provide the charge needed to switch the device. A change in input capacitance may therefore require engineers to reassess gate-drive conditions. Coss affects energy stored and released as the drain voltage changes, so shifts can influence switching losses. Crss contributes to drain-to-gate coupling and is also relevant when evaluating switching behavior and unwanted transients.
These effects are relevant to circuits such as buck and boost converters, where MOSFET switching performance is part of overall operation. The study cautions that changes in capacitance can affect switching applications even when the device remains functional. Circuit designers may need to review the gate driver and switching behavior rather than assume pre-irradiation characteristics remain valid.
Practical considerations for radiation-exposed systems
For system integrators and engineers qualifying power electronics for a radiation environment, the findings support several practical steps:
- Assess Ciss, Coss and Crss alongside static characteristics such as threshold voltage and drain current.
- Include relevant drain-source voltage conditions when comparing pre- and post-irradiation capacitance.
- Evaluate the specific MOSFET and its operating conditions; responses can differ between devices, including SiC components.
- Check gate-drive requirements and switching behavior against the post-irradiation characteristics that are relevant to the application.
- Interpret dose results in context. Device type, bias conditions and the intended circuit all matter when translating test observations into design decisions.
Laboratory characterization can identify changes in device behavior, but a system-level assessment is needed to understand their implications for a particular power circuit. A device that remains operational may still have capacitance shifts worth considering in converter design and qualification.
Conclusion
Cobalt-60 testing of Si and SiC power MOSFETs shows why radiation qualification should consider dynamic characteristics as well as conventional electrical parameters. TID-related changes to Ciss, Coss and Crss may influence gate charging, switching losses and circuit behavior, and the response can vary substantially between devices. For radiation-exposed power electronics, measuring capacitance-voltage characteristics and checking their impact on the gate driver and switching circuit can provide a more complete basis for design and qualification decisions.