Access Official Technical PDF

Share Summary:LinkedInEmail

In industrial automation electronics, capacitors in switching power supplies and other high-frequency circuits must be selected against the electrical and environmental conditions they will actually encounter. Organic semiconductor aluminum capacitors are designed for these kinds of applications, with low equivalent series resistance (ESR), high ripple-current capability, and operation at frequencies up to 300 kHz listed among their characteristics. Those features are only part of the selection process: operating temperature, working voltage, and the requirements of the circuit all need to be considered together.

What to assess in organic semiconductor aluminum capacitors

A capacitor’s nominal capacitance and rated voltage are important starting points, but they do not describe its entire behavior in a power circuit. ESR and ripple current can also matter in switching applications, where the component is exposed to alternating current as well as its DC working voltage.

The AFX series data lists very low ESR, stable performance with temperature, and ripple-current ratings up to 10.1 A. The standard part listing provides specific values by part number, capacitance, and rated voltage. It identifies maximum ESR over 100–300 kHz at 20°C and maximum RMS ripple current at 100 kHz and 45°C. These conditions matter: compare a listed rating with the circuit’s operating conditions rather than treating it as an unconditional value.

For example, when reviewing a candidate part for a switching power supply, engineers should check its capacitance and rated voltage alongside the listed ESR and ripple-current figures. They should also confirm that the specified measurement frequency and temperature are relevant to the intended design.

Temperature range and voltage derating

The stated operating temperature range is -55°C to +105°C. The specifications also caution that the working voltage must be derated above 85°C: reduce the voltage by 0.25 V for each 1°C above 85°C. A design operating in this upper temperature range therefore needs a working-voltage check, not just a comparison with the capacitor’s printed WVDC rating.

Temperature also appears in the published ripple-current multipliers. The table lists factors of 1.0 below 45°C, 0.85 at 45°C, 0.7 at 65°C, 0.4 at 85°C, and 0.25 at 95°C. Apply the appropriate factor when assessing ripple-current capability at the relevant temperature. Do not confuse these multipliers with the separate working-voltage derating instruction.

These checks are particularly relevant when selecting components for equipment that may operate in warm enclosures or experience changing thermal conditions. The system’s expected operating environment should inform the component choice and the design review.

Read the qualification limits as well as the ratings

The specification describes two endurance-related tests: load life for 2,000 hours at +105°C with rated WVDC, and moisture resistance for 1,000 hours without load at 60°C and 90–95% relative humidity. The document states that capacitors will meet specified limits after these tests, including limits for capacitance change, dissipation factor, and leakage current.

These test conditions provide useful qualification information, but they should not be mistaken for a guarantee of service life in every installation. Actual results depend on the application and its operating conditions. Engineers should review the complete part specification and apply their organization’s component qualification and reliability practices.

Use the part listing to narrow candidates

The standard part listing covers multiple capacitance and voltage combinations, from small capacitance values to higher-capacitance parts, with dimensions varying by part. It includes part numbers, maximum ESR, leakage current, ripple-current ratings, and physical dimensions. Use those fields to filter candidates against the circuit’s electrical requirements and available board space.

  • Confirm capacitance and WVDC: Match the required capacitance and ensure the rated voltage remains suitable after any required temperature derating.
  • Check ESR and ripple current: Compare the circuit conditions with the frequency and temperature attached to each listed rating.
  • Verify physical fit: Check the listed diameter-by-length dimensions and lead spacing against the PCB layout and assembly constraints.
  • Review options: The document lists special-order options including ammo pack, ±10% tolerance, and cut or formed leads.

Capacitance tolerance is specified as ±20% at 120 Hz and 20°C. The standard listing also gives maximum dissipation factor and leakage-current values, so these parameters can be checked where they are relevant to the design.

Practical implications for automation design

For system integrators and equipment designers, capacitor selection is a coordination task across electrical design, thermal assessment, and mechanical layout. A part that meets a nominal capacitance requirement may still need further review if its ESR, ripple-current rating, temperature exposure, or dimensions do not suit the application.

Organic semiconductor aluminum capacitors offer specifications intended for switching power supplies and high-frequency applications, including low ESR and high ripple-current ratings. To apply those characteristics responsibly, use the individual part data, observe the stated measurement conditions, and account for the specified voltage derating above 85°C. A disciplined review of electrical ratings, temperature limits, qualification conditions, and package dimensions helps teams make a better-informed component choice for industrial automation electronics.

Access Official Technical PDF

About The Author