Thermoreflectance imaging maps localized heating as electromigration develops in aluminum interconnects. Tests of an asymmetric void-and-reservoir structure show how bias polarity influences hot-spot locations and failure modes.
Articles Tagged: thermoreflectance imaging
Electromigration Imaging Reveals Interconnect Failure Risks
A study of asymmetric aluminum interconnects shows how thermoreflectance imaging can reveal localized heating and evolving damage during electromigration. The observed failure location changed with voltage polarity, underscoring the importance of geometry and local conditions when assessing interconnect reliability.