Vertical bifacial solar farms present a different design trade-off from conventional tilted photovoltaic arrays. Because bifacial modules can collect light on both faces, they can use direct sunlight as well as diffuse sky radiation and light reflected from the ground. But a panel’s output in isolation does not predict the performance of a farm: row-to-row shading, electrical configuration and local weather all affect how much of the available light becomes usable energy.
A global modeling analysis of ground-mounted, east-west-facing vertical arrays examined these interacting factors across locations. Its central practical finding is that, for a modeled 2 m row spacing and 1.2 m-high panels, vertical bifacial farms produced 10–20% more annual energy per land area than conventional monofacial farms in most regions considered. That comparison is not a guarantee for every site or project; design conditions and local irradiance matter.
How vertical bifacial solar farms collect light
A monofacial module generates electricity from its front face, while an opaque backsheet prevents it from using light arriving from behind. A bifacial module has optically active faces on both sides. In a vertical east-west arrangement, the east-facing side receives direct sun mainly in the morning, and the west-facing side receives it mainly in the afternoon. This can create two daily output peaks, with the later peak occurring closer to periods of high electricity demand in some settings.
Farm output draws on three irradiance components:
- Direct irradiance: sunlight arriving from the direction of the sun. Adjacent rows can cast shadows across a module or the ground.
- Diffuse irradiance: sunlight scattered by the atmosphere. Rows can obstruct part of the sky visible to a panel.
- Albedo: sunlight reflected from the ground onto a panel’s rear or front face. Its contribution depends on ground reflectance and on how much ground is illuminated and visible from the module.
These components vary by time and location. A site with more diffuse light, for example, does not necessarily respond to row spacing in the same way as a site dominated by direct sunlight.
Why row spacing and shading shape energy yield
Rows packed too closely can shade one another, reducing the light reaching the modules. In the modeled configuration, the effect is not simply a loss of illuminated area. Shading can be uneven across a panel’s height, leaving some cell sections with less light than others. The analysis accounted for this spatial variation and for panels divided into series-connected sub-strings protected by bypass diodes.
Bypass diodes help manage the electrical effects of shading by allowing a shaded sub-string to be bypassed. However, bypassing a section also changes the panel’s output. Consequently, collected irradiance and generated power are not always proportional: electrical connections influence how effectively a partially shaded module converts available light.
Increasing the distance between rows can reduce shading, but uses more land for each row and reduces the amount of generating equipment that fits within a given area. The design therefore has an optimum row period—the distance from one row to the next—when the objective is to maximize annual energy per unit of land. In the model, this optimum depends on panel height, sun path and the balance of direct and diffuse irradiance. Higher latitudes generally require greater spacing because the sun’s path creates longer shadows; at a given latitude, locations with a stronger diffuse-light contribution also tend toward larger optimum spacing.
Interpreting the modeled farm comparison
The analysis compared vertical bifacial farms with monofacial arrays under two kinds of spacing assumptions. When each design’s spacing was optimized for energy yield, monofacial arrays could have a strong advantage near the equator: their panels can be tilted relatively close to horizontal and spaced tightly. Such layouts may not be practical where installation, access and maintenance require more room between rows.
With a fixed 2 m row spacing—a practical allowance considered in the analysis for 1.2 m-high panels—the modeled vertical bifacial configuration outperformed the monofacial comparison by 10–20% in most regions. The study also identified locations where bifacial performance was lower, particularly some areas with low sky clearness. In those conditions, diffuse-light shading and the electrical penalty associated with uneven illumination can weigh more heavily on output.
The comparison used assumptions including ground reflectance of 0.5. Actual project assessments should therefore use site-relevant conditions rather than treating the modeled percentage as a guaranteed performance uplift. Ground reflectance, weather patterns, module characteristics, layout and electrical design all influence the result.
Energy yield is only one design criterion
A layout that maximizes annual energy per land area does not automatically minimize the levelized cost of electricity (LCOE). A project decision also needs to account for installation and equipment costs, land use, maintenance access and the economics of cleaning. The analysis notes that vertical panels may accumulate less dust or snow than conventional orientations, but reduced soiling should be evaluated for the specific operating environment rather than assumed as a fixed gain.
Similarly, the modeled energy advantage depends on a particular farm geometry and electrical representation. Changing row spacing or module configuration can alter shading and the amount of light that contributes to power production. Engineering teams should evaluate the whole array—not just the performance of a standalone bifacial panel—and compare energy yield with practical site and cost constraints.
Practical implications for solar farm planning
Vertical bifacial solar farms can be a viable option for large-scale generation, especially where practical row spacing, two-sided light collection and potential soiling considerations support the design. Their performance depends on how irradiance, ground reflection, row geometry and module circuitry work together. For engineers and project decision-makers, the key lesson is to model the farm at the site level: include direct, diffuse and reflected light, represent partial shading and bypass-diode behavior, and test spacing choices against both annual yield and project economics.